8 (7172) 36 08 13

  reklama-nst@mail.ru

HEATED FLOORS

Heated floors "TEPLOLUX" - it is a safe comfortable cable heating system. It can be used as the main heating system in separate buildings, where there is no possibility to connect to the central heating system or as an additional heating system (with another) to provide thermal comfort in rooms with cold floors (marble, tiles). "TEPLOLUX" system is used, as well, and in agriculture for heating of livestock farms.

The main advantages of our system are:

  • Cost-effective and the most efficient use of electricity
  • The maximum easy installation
  • Free from heaters surface of walls and floors, unlimited design solutions
  • Ravnoemernoe heat distribution on the floor and the height of the room
  • A modern thermo equipment
  • Long service life

The thermostat in each room significantly reduces power consumption and maintains the set you +10 0 ... +30 a C. Heated floors - create indoor thermal comfort and uniform heat distribution. The cost of installing systems for floor heating in the construction or repair - Minimal. To install the system is necessary to lay the heating cable a concrete screed, connect the thermostat and set it to the desired temperature. Finishing the floor covering can be anything of your choice: tile, marble, carpet. To heat the wooden floor (parquet or floor boards) heating cables are laid directly under the floor, the concrete screed.

FEATURES INSTALLATION: "underfloor" established, as a rule, on "clean" floor area not occupied by furniture or fixtures. This is primarily due to energy savings. . Reliability "underfloor" 99% is determined by the quality of installation work. WARRANTY: warranty period for heated floors "Teplolux" — 25 (the actual service life — in a few times more).

The system includes
teplolux1-sst
system "Teplolux" consists of:
  1. heating section
  2. Thermostat
  3. mounting tape
  4. protective corrugated tube for temperature sensor
The system uses single-core heating sections (type TLOE) or a two-core heating sections (type TLBE). Both sections are suitable for heating any premises, including residential, office, industrial. Sections have different lengths and capacities. Type section, specific and total capacity indicated on the cable sheath. different color skins are used for additional labeling.
Description
The main element of cable underfloor heating system is a heating cable that converts electrical energy into heat. The heating cable used in the form of segments of a certain length - heating sections. In addition to the heating section, in underfloor heating thermostat consists of a sensor for controlling the operation of the floor heating system and additional materials: insulation, mounting tape and corrugated tube assembly. Mounting tape used when laying the floor heating for fixing the heating section on the floor. Tube assembly serves as a protection for the floor sensor, providing access thereto for inspection or replacement. Thermal insulation reduces the heat loss, thereby increasing the efficiency of the floor heating and reduces power consumption. Depending on the magnitude of heat loss and options for application of floor heating insulation system applied with different technical parameters and a certain thickness. Heating part of the system (heating section of a special heating cable) is hidden in the floor structure in the cement-sand screed. Floor covering can be anything: tile, marble, laminate, carpet

Today, underfloor heating systems – one of the most popular. This is due to a number of advantages of such systems – their efficiency (30 to 50%), durability, safety (you can not worry that children will burn as it can happen with a radiator heating). Compared with a radiator, underfloor heating on the procedure more comfortable thanks to the use of different modes (control with outdoor temperature, manual mode and temperature limitation mode).

mini-sst25

If you want to equip yourself a warm floor in the first place is to deal with its basic element, without which the system simply will not work, – This mixing unit underfloor heating. Individual craftsmen promote the idea of a warm water floor, equipped only with the three-way valve and pump without the use of – but it is a pilot version, which may be of interest unless the art, as an example of the original decision.

Underfloor heating Site: operating principle and configuration

The water temperature in the radiator heating system can reach 80-90 degrees Celsius. The temperature of the floor under the rules should not exceed 26 degrees. The main problem to be solved by the floor heating unit – This lowering of the temperature to the desired level by means of admixing water treatment (so that it can be connected to the radiator and the heating system) and provide a desired temperature of water circulating in the floor loop.

The main elements of the collector unit – This circulation pump, flow and return manifolds, control valves, thermostatic controls and consumption.

When choosing a circulating pump for the system, pay attention to the indicator of pressure – the higher it is, the faster the flow. In addition, the flow rate can affect the system capacity or the node.

tlmini

The control valve may be a two- or three-way. The first changes the capacity of the medium (its flow), moving the valve plug or valve plug. Three-way – mixes or divides flow. In addition to regulating, to valves entrusted with the functions such as shut-off, mixing and separation (Distribution). Many experts believe the collector assembly underfloor heating with two-way valve more acceptable as it does not allow overheating of the floor and due to the small capacity can ensure a stable and smooth temperature control. Nonetheless – they are not recommended in areas with an area exceeding 200 square meters.

Thanks to the flowmeters can be uniform circulation of coolant; task thermostatic controls – to respond to the external environment and to maintain the required temperatures by changing a single loop temperature.

Underfloor heating Site: mix styles

Today, the market offers units with serial and parallel types of mixing. Serial type more logical in terms of heat engineering, since the temperature of the stream exiting the mixing unit in the direction of the boiler, a temperature equal to the floor. Another advantage of the series circuit – the possibility of placing more circuits. Plus the use of parallel type – the possibility of using a single two-way valve; but this advantage turns fickle consumer spending.